The Span America Easy Air "LR" Lateral Rotation hospital bed mattress system is designed for patients with a risk or getting bed sores or with bed sores and pressure wounds. The Span America mattress is a USA made mattress that features both foam and air materials and is durable and reliable with a 2 year warranty. PressureGuard®Easy Air® LRLow-air-loss Therapy with Alternating Pressure or Lateral RotationAll of the most needed features in one surface.Start with the popular PressureGuard Easy Air®, the low-air-loss surface independently documented to outperform every leading low air loss system in moisture removal.Add the alternating pressure and lateral rotation modalities found in the effective PressureGuard APM2.The result: The most versatile, multi-modality surface on the market.Remarkably, it does so with none of the compromises low air loss users have come to accept, thanks to its exclusive Air Diffusion Matrix technology and PressureGuard air/foam design.Easy Air LR won't lose inflation in a power outage. Its stable surface won't "swallow up" the user. And its Safety Edge™ won't collapse like air-only mattresses can, making transfers safer. It won't make the user too hot or too cold, either.Ultra-simple to set up, clean and use. Comfort level is adjustable. "On/off" buttons control air flow and alternating pressure/lateral rotation/ float feature.PressureGuard Easy Air® LR Recessed Deck ModelThe recessed deck versions of selected Span surfaces, including the Easy Air LR, brings our advanced technology to recessed deck beds. Our engineers have developed a version of the Easy Air LR surface to accommodate the unique design requirements of recessed deck beds. V-shaped edges enable the mattress to fit the recessed deck bedframe, while the compressible section accommodates multiple lengths and foot positions.Patented design creates an inner bolster “cradle” effect for added safety when the patient sits on or moves toward the bed edge. This protective feature helps direct the patient’s center of gravity safely back toward the center of the bed. Two sturdy fabric handles improve relocation ergonomics. Visit the recessed deck surfaces page. Inner Bolster “Cradling” for Patient SafetyCompressible section adds length flexibilityWeight limit: 500 lbs. in FLOAT and ALTERNATING, 350 lbs. in ROTATION.Mattress weight: 22 lbs.Warranty: 2-years, non-prorated, all components.UL listedThe PressureGuard Easy Air® LR is recognized for reimbursement under Medicare Code: E0277.Weight limit and warranty specifications for the Easy Air LR Recessed Deck Model same as Standard Easy Air LR.Contact us for pricing on this Span America mattress model and other air mattress models that can fit on used-refurbished Hill Rom and Stryker hospital beds.San Diego California 858-263-4894Richmond Virginia 804-929-6886sean@imedequipservices.comwww.imedicalshop.com
www.1hospitalbeds.com
The Stryker inTouch bed is a full electric hospital bed that comes with an
air mattress system. The bed includes an "XPRT" air mattress with percussion and
pulmonary features and also a "Position Pro" mattress that includes lateral rotation
and low air loss, which the XPRT mattress also includes.
This hospital bed is ideal for patients at risk of getting bed sores, skin ulcers and pressure wounds.
The hospital bed is sold from our California and Virginia locations.
Stryker Intouch Hospital Bed Prices
with XPRT mattress $3,995
with Position Pro mattress $3,495
Stryker InTouch Hospital Bed Video Demonstration
San Diego California Air Mattress Bed
Richmond Virginia Air mattress Hospital Bed(s) Stryker InTouch
Stryker InTouch Bed with XPRT mattress. This demo video shows one of the best air mattress hospital beds made in the USA. InTouch bed instructions and walk through.
https://www.1hospitalbeds.com (858) 263-4894 California (540) 327-7376 Virginia
Email us for more information at hospitaldirectmedical@gmail.com
Looking for a hospital bed with a built in air mattress system that can help treat and prevent bed sores, pressure wounds, skin ulcers and other types of skin breakdown? The Stryker InTouch bed provides a low air loss mattress, lateral rotation and percussion-vibration pulmonary functions. Contact us at Hospital Direct Medical Equipment Inc. at hospitaldirectmedical@gmail.com
Product
width
Siderails up 42 in.
Siderails down 40 in.
Base Under product clearance 5 in.
Patient surface
• Width
• Length
• Length (with optional bed extender)
• 35 in.
• 84 in.
• 90 in.
Seat depth 18.5 in. 47 cm
Foot
• Length
• Angle
• 29 in.
• 0° to 50° (± 5°)
• 73,7 cm
• 0° to 50° (± 5°)
Fowler width 36 in.
Fowler length 34 in. to 35 in
Fowler angle
• 0° to 70°
• (0°-40° and 50°-70° ±
3°)
• (40°-50° ± 5°)
• 0° to 70°
• (0°-40° and 50°-70° ±
3°)
• (40°-50° ± 5°)
Gatch
• Width
• Length
• Angle
• 18 in.
• 34 in. to 35 in.
• 0° to 15° (± 3°)
Cardiac chair position
• Standard
• Enhanced
• Head: 65°, Seat: 17°, Foot: 30°, Trend: 3°
• Head: 70°, Seat: 19°, Foot: 47°, Trend: 3°
Fowler Length 36.5 in. 92,7 cm
Lift system
Height (high) to top of litter 33 in
Height (low) to top of litter 16 in.
Trendelenburg/Reverse Trendelenburg 12° (± 2°)
Product lift time 35 seconds maximum from lowest to highest position
Scale system
Capacity 550 lb 249 kg
Accuracy:
• For weight from 100 lb to 550 lb
•
For weight from 100 lb to 550 lb
• For weight under 100 lb
•
For weight under 100 lb
± 2% when in Trendelenburg or Reverse Trendelenburg
± 2% when flat
± 2 lb when in Trendelenburg or Reverse Trendelenburg
± 2 lb when flat
CPR system
Speed to level product from any position
•
Fowler
• Foot and seat
• 15 seconds
• 60 seconds
Stryker Intouch Bed Overview Video “New, Refurbished and Surplus Medical Equipment and Service”
San Diego, California
4901 Morena Blvd. #600
San Diego Ca., 92117
Phone (858) 263-4894
Richmond, Virginia
11351 International Drive
Richmond Virginia, 23236
Phone: (804) 929-6886
We get emails every single day from caregivers and patients in need of an air mattress system and hospital bed for patients with bed sores, skin ulcers, pressure wounds or at risk of getting bed sores. Every so often we get a request for a Hill Rom Clinitron bed, which are rarely used
in hospitals. Here is an email and a reply we provided to an actual email for a quadriplegic patient that has stage 4 bed sores and bed models and choices for this patient.
We ship and deliver beds all over the United States. We have locations in San Diego California, Richmond Virginia and also Cincinnati Ohio which allows us the ability to provide showrooms to see the beds and also deliver them with our own staff.
Contact us below for more information or to see beds, order bed models or get shipping and delivery quotes.
Hospital Beds for Stage IV Bed Ulcers Bed Sores Date/Time: 2/23/2019 3:25:47 PM Email Message: Home Health Skilled Nursing patient needs Clintron Hospital model with hi-low and wheels for Quadriplegic with Stage IV bed sores - do you have it? what do you recommend?
Hi Penelope,
We do not carry the Clinitron bed - unfortunately hospitals really do not use them anymore since they run on small beads and those need to be all taken out, cleaned for each patient and can expand in humid conditions and plug the mattress system.
We do offer the following beds and mattress systems from Hill Rom and Stryker
Hill Rom Progressa bed - new $65,000 - refurbished with 1 year warranty $25,000.00
These are the newest beds made with a low air loss mattress, lateral rotation feature, percussion-vibration, chair position and made to treat and prevent bed sores. (1) bed in stock - very hard to get refurbished since it is a newer bed model https://www.1hospitalbeds.com/hill-rom-progressa-bed/
Hill Rom Totalcare Sport 2 new $55,000 refurbished $5995.00 refurbished with 1 year warranty $8995.00
Stryker InTouch Bed new $45,000 refurbished $3,995 - with one year warranty $6995.00
All of the same features as the beds above however it does not have a chair position where the feet touch the ground. The InTouch bed has a low air loss mattress, lateral rotation feature, percussion-vibration, chair position and made to treat and prevent bed sores.
These are the models we have that are made for acute care patients with bed sores or at risk of getting bed sores. Let me know if you have questions or need anything else.
Thanks,
Sean
858-652-1259
Hospital Direct Medical Equipment “New, Used and Surplus Medical and Hospital Equipment”
4901 Morena Blvd. #600 San Diego Ca., 92117 9AM to 5PM Mon-Fri 10AM to 2PM Saturday USA Office phone: (858) 263-4894 USA Email: hospitaldirectmedical@gmail.com
Richmond and White Post - Winchester Virginia 1114 Fairfax Pike, #212 White Post, Virginia 22663 Phone: (540) 327-7376 USA Email: hospitaldirectmedical@gmail.com
Mexico / Latin America Gloria Flores (858) 263-4894 Cell 858-922-6862
Hospital Grade Air Flow Mattress Systems for Preventing Bed Sores
Hill Rom P1900 TotalCare Sport Bed and Hill Rom P3200 Versacare Bed -
Made with air mattresses to treat and prevent bed sores.
There are several ways to integrate an air mattress system into a hospital
bed and one of the most popular is adding an "air mattress" with separate
pump that hangs off the foot of the bed. These "replacement air mattress
systems can come as pressure redistribution mattresses and also with a
feature called "low air loss", which runs a layer of air conditioned air
over the top of the mattress to prevent sweating.
The Sentry 1400 is a commercial grade pressure redistribution, low air
loss mattress system that is used in hospitals and also for home use with
a special microfiber top layer that pulls moisture from the patient.
Replacement Air Mattress System Models and Choices
The Sentech "Sentry 1400" Low Air Loss Replacement Mattress
comes in 36 inch, 38 inch and 42 inch bariatric size for patient
weight up up to 500 pounds.
The Sentry 1400 is our best low air loss replacement mattress
system is one of the best hospital grade mattress systems
sold in the USA. We can sell this replacement air mattress brand new
priced at ONLY 3,477 and include free shipping. Order this
replacement mattress system by calling us at 858-263-4894
or ask questions via email at hospitaldirectmedical@gmail.com
Sentry 1400 Replacement Air Mattress System
The Sentry 1400 offers the therapeutic results and features you would expect to find in far more expensive systems. Incorporated into every Sentry 1400 mattress system is the assurance of superior technology, state of the art features and proven pressure relief.
The Sentry 1400 offers the therapeutic results and features you would expect to find in far more expensive systems. Incorporated into every Sentry 1400 mattress system is the assurance of superior technology, state of the art features and proven pressure relief.
The Sentry 1400 provides Our Patented Microvent Technology Low Air Loss, Alternating Pressure, Static/Float mode, Fowler Boost and additional inflatable bolsters.
Sentech Sentry 1400 low air loss, pressure redistribution replacement mattress system
sold new with a one year warranty - good for hospital grade use or for home use.
Our number #1 selling mattress priced at ONLY $3,477.00. Many of these air
mattress systems can easily cost over $10,000. Call to order 858-263-4894 or
visit "replacement air mattress systems" for more information.
ArjoHuntleigh DFS3 Air Mattress Systems
The air flow mattress systems are designed to prevent bed sores and are
also used for wound care, burn patients and other types of medical
specialties.
We currently have the ArjoHuntleigh DSF3 Air mattress systems in
stock in good working order ready for immediate sale. OUT OF STOCK
Used ArjoHuntleigh DFS3 Mattress Systems for Sale
About the DFS3 Mattress systems
The DFS3 mattress replacement is a true dynamic system providing effective alternating pressure relief with automatic adjustment to the weight, size and position of the individual patient, ensuring optimum pressure redistribution and comfort.
Since 1989, the DFS Advanced Dynamic Flotation System has been clinically proven to be one of the most effective, comfortable, yet cost efficient, pressure relieving mattress replacement systems used in hospitals and nursing homes throughout the world.
Hospital Direct Medical Equipment“New, Used and Surplus Medical and Hospital Equipment”
4901 Morena Blvd. #506
San Diego Ca., 92117
9AM to 5PM Mon-Fri
10AM to 2PM Saturday
USA Office phone: (858) 731-7278
Office #2 (858) 263-4894
USA Email: hospitaldirectmedical@gmail.com
AIR MATTRESS PRESSURE RELIEF INDEX
The DFS 3 System effectively relieves pressure below clinically relevant thresholds close to arteriolar, capillary and venule operating pressures nominally at 30, 20 and 10 mm Hg for longer periods of time.
This enables blood vessel diameters to remain as large as possible for as long as possible ensuring tissue oxygenation and nutrition are maintained and the removal of toxins is stimulated. Ths aids in the effective prevention and treatment of pressure ulcers.
Related Links and Articles on Bed Sores, Skin Ulcers and Replacement Mattresses